Mitsubishi FR-D720-318-NA-LX VFD Inverter 7.5kW / 10HP FRD720318NALX

$1,080.00

AVAILABILITY: Generally allow 7-10 days to ship

Mitsubishi FR-D720-318-NA-LX Variable Speed/Frequency Drive (VSD/VFD) / Inverter – US/CA/MX specification – LX type – Mitsubishi Electric (FREQROL FR-D700 series) – 3-phase (3P) 200V class – input 200Vac-240Vac (220Vac / 230Vac nom.) – 7.5kW / 10HP – 31.8A – frequency (output) 0.2-400Hz – with Modbus RTU + RS-485 communication capability – IP20 – equivalent to FRD720318NALX

 

SKU: FR-D720-318-NA-LX Category: Tag: Brand:
  • Same-day shipping on in-stock items ordered by 4:00 PM Eastern
  • 1-year warranty on most products

Description

Mitsubishi FR-D720-318-NA-LX VFD Inverter 7.5kW / 10HP FRD720318NALX

  • Extended Product Type: Inverter
  • Product ID: FR-D720-318-NA-LX
  • Mitsubishi Type Designation: Inverter

Description of Mitsubishi FR-D720-318-NA-LX VFD Inverter 10HP

Mitsubishi FR-D720-318-NA-LX Variable Speed/Frequency Drive (VSD/VFD) / Inverter – US/CA/MX specification – LX type – Mitsubishi Electric (FREQROL FR-D700 series) – 3-phase (3P) 200V class – input 200Vac-240Vac (220Vac / 230Vac nom.) – 7.5kW / 10HP – 31.8A – frequency (output) 0.2-400Hz – with Modbus RTU + RS-485 communication capability – IP20 – equivalent to FRD720318NALX

Specifications of Mitsubishi FR-D720-318-NA-LX VFD Inverter 7.5kW / 10HP

  • Primary brand: Mitsubishi Electric
  • Main function: Variable Speed/Frequency Drive (VSD/VFD) / Inverter
  • Product series/family name: FREQROL FR-D700 series
  • Type of network: 3-phase / 3P
  • Network frequency: (output) 0.2-400 Hz
  • Functions: Variable Speed/Frequency Drive (VSD/VFD) / Inverter
    • Soft-PWM control
    • High carrier frequency PWM control
    • Maximum/minimum frequency setting
    • Frequency jump operation
    • External thermal relay input selection
    • Automatic restart after instantaneous power failure operation
    • Forward/reverse rotation prevention
    • Remote setting
    • Second function
    • Multi-speed operation
    • Regeneration avoidance
    • Slip compensation
    • Operation mode selection
    • Offline auto tuning function
    • PID control
    • Computer link operation (RS-485)
    • Optimum excitation control
    • Power failure stop
    • Speed smoothing control
  • Design: North American (NAm) specification, Forced air cooling
  • Supply voltage (AC): 200Vac-240Vac (208Vac / 220Vac / 230Vac)
  • Rated current: 31.8A, 150% In for 60s / 200% In for 0.5s overload current rating (inverse-time characteristics)
  • Rated active power (kW): 7.5kW
  • Rated power (HP): 10HP
  • Protection functions: Overcurrent during acceleration
    • overcurrent during constant speed
    • overcurrent during deceleration
    • overvoltage during acceleration
    • overvoltage during constant speed
    • overvoltage during deceleration
    • inverter protection thermal operation
    • motor protection thermal operation
    • Heatsink overheat
    • output short circuit
    • parameter error
    • PU disconnection
    • CPU fault
    • brake transistor alarm
    • inrush resistance overheat
    • analog input error
    • stall prevention operation
    • Safety circuit fault
    • Output phase loss
    • Output side earth (ground) fault overcurrent at start
    • External thermal relay operation
    • PTC thermistor operation
    • Retry count excess
    • output current detection value exceeded
    • Input phase loss
  • Communication protocol: Modbus RTU
  • Digital inputs: 1 x digital input (source/sink) (STF)
    • 1 x digital input (source/sink) (STR)
    • 1 x digital input (source/sink) (RH)
    • 1 x digital input (source/sink) (RM)
    • 1 x digital input (source/sink) (RL)
    • 1 x digital input (safe stop channel 1)
    • 1 x digital input (safe stop channel 2)
  • Digital outputs: 1 x digital output (SPDT (Single Pole Double Throw contact A/B/C) (programmable)
    • 1 x digital output (open collector transistor) (programmable)
    • 1 x digital output (PTO Pulse Train Output for indicator)
    • 1 x digital output (programmable) (SO – Safety Monitor Output)
  • Analog inputs: 1 x analog input (0-5Vdc / 0-10Vdc), 1 x analog input (0-5Vdc / 0-10Vdc / 4-20mA)
  • Degree of protection: IP20
  • Order code / Manufacturer SKU: FR-D720-318-NA-LX
  • Equivalent to: FRD720318NALX
  • Rated apparent power (S): 12.7kVA
  • Application type: Transfer, Lift, Packaging, Machine tool, Air conditioning, Fan, Pump
  • Compliant with standard(s): EN ISO 13849-1 Category 3, EN62061. IEC61508 SIL2 PLd
Benefits & Features Improved reliability and easy maintenance – Spring clamp terminals provide high reliability and easy wiring. – Shutoff circuit (hardware) securely provides emergency output shutoffs. The inverter with the safety stop function can comply with the safety standards without incurring too much cost. – Parameter writing/reading can be restricted with a 4-digit password. Pursuing the best performance – The General-purpose magnetic flux vector control and the auto tuning function enable reliable operation in applications that require large starting torque. (150% 1Hz‚ 200% 3Hz (3.7K or lower with the slip compensation)) Easy-to-use (pursuing the easy operation) – The non-slip‚ adaptable scroll speed setting dial allows for quick jumps or precise increments based on turning speed. – An enclosure surface operation panel‚ which can be attached on an enclosure surface‚ is available as an option. – The inverters with 0.4K or higher capacity have built-in regenerative brake transistors‚ and their usage can be extended to a lift application. Environmentally friendly – Filter options reduce the electromagnetic noise generated at the inverter and enables the compliance with the harmonic suppression guidelines of Japan.

Additional information

Weight 16 lbs
Dimensions 10 × 10 × 12 in