Description
Mitsubishi FR-A840-00380-2-60 Inverter 15kW / 20HP A800 FRA84000380260
- Extended Product Type: Inverter
- Product ID: FR-A840-00380-2-60
- Mitsubishi Type Designation: Inverter
Description of Mitsubishi FR-A840-00380-2-60 Inverter A800
Mitsubishi FR-A840-00380-2-60 Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating + CA term. (0-20mA) – Mitsubishi Electric (FREQROL FR-A800 series) – 3-phase (3P) 400V class – input 380Vac-500Vac (400Vac / 415Vac / 480Vac nom.) – 15kW / 20HP – 31A (ND Normal duty) – frequency (output) 0.2-590Hz – with Modbus RTU + RS-485 communication capability – IP20 – Chemical resistance (circuit board coating – IEC60721-3-3 3S2 3C2) – equivalent to FRA84000380260 TorqueSpecification of Mitsubishi FR-A840-00380-2-60 Inverter A800
- Primary brand: Mitsubishi Electric
- Main function: Variable Speed/Frequency Drive (VSD/VFD) / Inverter
- Product series / family name: Industrial automation > Drive products > Inverter systems > VFDs > FREQROL FR-A series
- Sub-range name: FREQROL FR-A800 series
- Network frequency: (Supply input) 50/60 Hz; (output) 0.2-590 Hz
- Functions: Variable Speed/Frequency Drive (VSD/VFD) / Inverter, Soft-PWM control, High carrier frequency PWM control, Selectable among V/F control, Advanced magnetic flux vector control, Real sensorless vector control, Optimum excitation control, PM sensorless vector control, Maximum/minimum frequency settings, Multi-speed operation, Acceleration/deceleration pattern, Thermal protection, DC injection braking, Starting frequency, JOG operation, Output stop (MRS), Stall prevention, Regeneration avoidance, Increased magnetic excitation deceleration, Frequency jump, Rotation display, Automatic restart after instantaneous power failure, Electronic bypass sequence, Remote setting, Automatic acceleration/deceleration, Retry function, Carrier frequency selection, Fast-response current limit, Forward/reverse rotation prevention, Operation mode selection, Slip compensation, Droop control, Load torque high-speed frequency control, Speed smoothing control, Traverse, Auto tuning, Applied motor selection, Gain tuning, RS-485 communication, PID control, PID pre-charge function, Easy dancer control, Cooling fan operation selection, Stop selection (deceleration stop / coasting), Power failure time deceleration-to-stop function, Stop-on-contact control, PLC function, Life diagnosis, Maintenance timer, Current average monitor, Multiple rating, Speed control, Torque control, Position control, Pre-excitation, Torque limit, Test run, 24V power supply input for control circuit, Safety stop function, Anti-sway control, Low-speed range speed control P gain, Shortest-time torque startup, Inching time adjustment function, Brake sequence, DC feeding
- Design: conformal coating, CA term. (0-20mA), 3-phase (3P) 400V class, Forced air cooling
- Supply voltage (AC): 380Vac-500Vac (400Vac / 415Vac / 480Vac nom.)
- Type of network: 3-phase/3P
- Rated current: 31A (ND Normal duty), 38A (SLD Super light duty), 35A (LD Light duty), 23A (HD Heavy duty), 150% In for 60s / 200% In for 3s overload current rating (inverse-time characteristics; Normal duty; 50°C ambient air temperature), 110% In for 60s / 120% In for 3s overload current rating (inverse-time characteristics; Super light duty; 40°C ambient air temperature), 120% In for 60s / 150% In for 3s overload current rating (inverse-time characteristics; Light duty; 50°C ambient air temperature), 200% In for 60s / 250% In for 3s overload current rating (inverse-time characteristics; Heavy duty; 50°C ambient air temperature)
- Rated active power (kW): 15kW (ND Normal duty), 18.5kW (SLD Super light duty), 18.5kW (LD Light duty), 11kW (HD Heavy duty), Rated power (HP), 20HP (ND Normal duty), 25HP (SLD Super light duty), 25HP (LD Light duty), 15HP (HD Heavy duty)
- Protection functions: Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip, Motor overload trip, Heatsink overheat, Stall prevention stop, Upper limit fault detection, Lower limit fault detection, Output side earth (ground) fault overcurrent, Output short circuit, Output phase loss, Option fault, Communication option fault, Parameter storage device fault (control board), PU disconnection, CPU fault, Operation panel power supply short circuit/RS-485 terminals power supply short circuit, 24Vdc power fault, Communication fault, Analog input fault, USB communication fault, Safety circuit fault, Internal circuit fault, Not available in initial status (Loss of synchronism detection, External thermal relay operation, PTC thermistor operation, Retry count excess, Abnormal output current detection, Overspeed occurrence, Brake sequence fault, 4mA input fault, Pre-charge fault, PID signal fault, Opposite rotation deceleration fault), Brake transistor alarm detection, Instantaneous power failure, Undervoltage, Input phase loss, Inrush current limit circuit fault
- Communication protocol: Modbus RTU, RS-485
- Digital inputs: 1 x digital input (source/sink) (STF)
- 1 x digital input (source/sink) (STR)
- 1 x digital input (source/sink) (STOP)
- 1 x digital input (source/sink) (RH)
- 1 x digital input (source/sink) (RM)
- 1 x digital input (source/sink) (RL)
- 1 x digital input (source/sink) (JOG)
- 1 x digital input (source/sink) (RT)
- 1 x digital input (source/sink) (MRS)
- 1 x digital input (source/sink) (RES)
- 1 x digital input (source/sink) (AU)
- 1 x digital input (source/sink) (CS)
- 1 x digital input (SS1 safe stop channel 1)
- 1 x digital input (SS1 safe stop channel 2)
- Digital outputs: 1 x digital output (SPDT Single Pole Double Throw contact A1/B1/C1) (fault output)
- 1 x digital output (SPDT Single Pole Double Throw contact A2/B2/C2) (programmable)
- 1 x digital output (sink/source open collector transistor) (RUN; programmable)
- 1 x digital output (sink/source open collector transistor) (SU; programmable)
- 1 x digital output (sink/source open collector transistor) (IPF; programmable)
- 1 x digital output (sink/source open collector transistor) (OL; programmable)
- 1 x digital output (sink/source open collector transistor) (FU; programmable)
- 1 x digital output (programmable) (SO – Safety Monitor Output)
- Analog inputs: 1 x analog input (0-5Vdc / 0-10Vdc / 0-20mA)
- 1 x analog input (-5…+5Vdc / -10…+10Vdc)
- 1 x analog input (0-5Vdc / 0-10Vdc / 4-20mA)
- Analog outputs: 1 x analog output (-10…+10Vdc; 8-bit) (signal output)
- 1 x analog output (0-20mA) (current output; CA term.)
- Degree of protection: IP20
- Ambient air temperature for operation: -10…+40 °C
- Chemical resistance: Chemical resistance (circuit board coating – IEC60721-3-3 3S2 3C2)
- Customs Tariff Number: 85049099
- Rated apparent power (S): 24kVA (ND Normal duty), 29kVA (SLD Super light duty), 27kVA (LD Light duty), 18kVA (HD Heavy duty)
- Order code / Manufacturer SKU: FR-A840-00380-2-60
- Manufacturer product status: Commercialized
- Equivalent to: FRA84000380260
- Compliant with standard(s): IEC61508, ISO13849-1, IEC61800-3, UL, cUL, CE, EAC, RoHS, China RoHS, Chinese GB standards, IEC60721-3-3 (3S2; 3C2), SIL3, PLd
- Application type: Transfer, Lift, Food Packaging, Machine tool, Press, Printing, Winding/unwinding
Benefits: Features
Pursuing optimum functions to meet our customers’ needs A lineup of dedicated inverters for specialized fields are offered.
Plus! The optimum functions for each dedicated field are added to the already high performance and high functionality FR-A800 series inverter.
Optimum functions for cranes
– Reduction in tact time
– By using the Mitsubishi Electric’s original anti-sway control technology‚ the swinging of an object moved by a crane is suppressed at the time of stopping‚ even without operator’s input adjustment.
This control cuts down the tact time and facilitates efficient operation.
– Load slippage prevention
– The highly scalable brake sequence function enables the output of a brake opening signal for the optimum brake operation calculated from the load torque or the speed.
– Slippage during the start of a lift can be checked.
(A speed detector such as an encoder is required.)
– Dedicated monitoring functions
– A signal can be output when too much load is applied.
– The inverter starting times can be counted to determine the timing of the maintenance.
Optimum functions for roll to roll applications
– System simplification
– The FR-A800-R2R inverter has various dedicated functions for dancer control and tension control (winding diameter calculation‚ etc.)‚ providing stable winding/unwinding control independently.
– Easy startup and adjustment
– Mechanical adjustment according to applications can be achieved just by setting parameters‚ which enables the startup and adjustment work of the system by the inverter alone.
(PI gain automatic adjustment function)
– Wide range of applications
– The inverter offers four types of control functions which enables the use in various system applications such as winding/unwinding in the wire drawing machines and printers.
– Dancer feedback speed control
– Tension sensor feedback speed control
– Tension sensorless torque control
– Tension sensor feedback torque control
Liquid Cooled Type Inverter
– Effective solution for downsizing of the enclosure
– A smaller enclosure can be used since the quantity of the heat dissipated in the enclosure is reduced.
– Dedicated monitoring functions
– A sensor (flow switch) is attached at the inlet of coolant to send a signal to the inverter.
When the coolant flow rate decreases‚ a warning is output‚ enabling quick‚ direct detection of system faults.
Logistics/Transport Dedicated Inverter
– Full-closed control
– This function is used to operate logistics/transport equipment in combination with distance meters and the host controller.
The logistics/transport equipment is moved while position loop is compensated by inputting the feedback of the position detected by the distance meter.
– Reducing tact time
– Anti-sway control
– This function minimizes the swinging of the crane frame while the shuttle car is traveling.
This will contribute to tact time reduction as less time is required for the swinging to stop
– System support
– Network The master gives the start command‚ speed command‚ or stop position command to the inverters through communication for the driving control