| Model |
ZX-GTC11 |
ZX-GTC41 |
| Output type |
NPN |
PNP |
| Measurement cycle *1 |
1.5 ms (standard mode (NORM)) 0.5 ms (high-speed mode (FAST)) *2 |
| Samples to average |
1/2/4/8/16/32/64/128/256/512/1,024/2,048/4,096 |
| Analog output *3 |
For current output: 4 to 20 mA/F.S., max. load resistance 300 Ω For voltage output:
±4 V, (±5 V, 1 to 5 V *4), output impedance 100 Ω |
| Timing input, bank switching
input, zero reset input,
reset input |
ON: short-circuited with 0 V or 1.5 V max.
OFF: Open (leakage current: 0.1 mA max.) |
ON: short-circuited with power supply
voltage or power supply voltage .1.5 V max.
OFF: Open (leakage current: 0.1 mA max.) |
| HIGH/PASS/LOW Judgment
output *5 Sync output *6 |
NPN open-collector output
30 VDC 50 mA max.
Residual voltage 1.2 V max. |
PNP open-collector output
30 VDC 50 mA max.
Residual voltage 2 V max. |
| Indicator |
Judgment output indicator: HIGH (orange), PASS (green), LOW (orange)
Main display (red) Sub-display (yellow) Bank 1/2 (orange), zero reset (green) |
| Main
functions |
Number of
registered setups |
2 banks |
| Measurement
Mode |
Interrupted beam width measurement, incident beam width measurement, outer
diameter measurement, center position measurement, IC lead pitch, IC lead width
judgment, specified edge measurement, wire position measurement, glass edge
position measurement |
| Display during
measurement |
Measured value, resolution, threshold, voltage output value, current output value
(number of display digits can be changed) |
| Zero reset
functions |
Offset setting of zero reset value, zero reset value memory |
| Hold |
Sample hold, peak hold, bottom hold, peak-to-peak hold, average hold, delay hold |
| Timer functions |
ON delay, OFF delay, one-shot |
| Adjustment
functions |
Optical Axis adjust mode/light intensityt writing mode, variable binary level, variable
edge filter, analog output scaling |
| Calculation |
2 Possible on up to two Controllers (Calculation Unit ZX-CAL2 is required for
connecting Controllers to each other.) A-B, A+B, width |
| Other |
Measurement cycle setting, threshold setting, hysteresis setting, initialization, key lock |
| Temperature characteristic |
0.005%F.S./°C |
| Current consumption |
150 mA max. with power supply voltage of 24 VDC (including receiver) *7 |
| Power supply voltage |
24 VDC +10%, .15% ripple (p-p) 10% max. |
| Dielectric strength |
1,000 VAC, 50/60 Hz for 1 min |
| Insulation resistance |
20 MΩ (at 500 VDC) |
| Ambient temperature |
Operating: 0 to 50°C Storage: .15 to 60°C (with no icing or condensation) |
| Ambient humidity |
Operating and storage: 35% to 85% (with no condensation) |
| Vibration resistance
(durability) |
10 to 150 Hz Single-amplitude: 0.35 mm for 80 min each in X, Y and Z directions |
| Shock resistance (durability) |
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) |
| Degree of protection |
IEC60529 IP20 |
| Cable length |
2 m |
| Material |
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate |
| Weight (packed state) |
Approx. 330 g |
| Accessories |
Instruction Sheet |