Yaskawa CIMR-AU2A0030FAA AC Drive 10HP 30A CIMRAU2A0030FAA

$2,380.00

AVAILABILITY: Generally allow 7-10 days to ship

10 in stock

SKU: CIMR-AU2A0030FAA Category: Tag:

Description

Yaskawa CIMR-AU2A0030FAA AC Drive 10HP 30A CIMRAU2A0030FAA

  • Extended Product Type: AC Drives
  • Product ID: CIMR-AU2A0030FAA
  • Yaskawa Type Designation: AC Drives

Description of Yaskawa CIMR-AU2A0030FAA AC Drive 10HP

Yaskawa CIMR-AU2A0030FAA Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) / Inverter – USA region – Yaskawa (A1000 series) – Input voltage (3-phase (3P)) 200Vac-240Vac (208Vac / 220Vac / 230Vac) – Rated active power 10HP (Normal duty) – Rated output current 30A (Normal duty) – frequency (output) 0.01-400Hz – IP20 / NEMA 1 – with RS-422 + RS-485 communication capability – Wall mounting – Forced ventilation (Fan-cooling) (Standard heatsink fins) – 3-phase 240V class – ordering code CIMRAU2A0030FAA

Specification of Yaskawa CIMR-AU2A0030FAA AC Drive 10HP 30A

  • Primary brand: Yaskawa
  • Main function: Variable Speed/Frequency Drive (VSD/VFD) / Inverter
  • Product series / family name: A1000 series
  • Network frequency: (output) 0.01-400 Hz, (input) 50/60 Hz
  • Functions: Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) / Inverter – USA region, Droop Control, Speed/torque Control Switching, Feed Forward Control, Zero servo function, Speed search, Over torque-detection, Under-torque detection, Torque limit, 17-step speed, Acceleration/Deceleration time switch, S-curve acceleration/deceleration, 3-wire sequence, Auto-tuning, Dwell, Cooling fan on/off switch, Slip compensation, Torque compensation, Frequency jump, Upper/lower limits for frequency reference, DC injection braking at start and stop, Overexcitation braking, High slip braking, PID control, Energy saving control, Fault restart, Application presets, Backup, Online tuning, KEB, Overexcitation deceleration, Inertia (ASR) tuning, High Frequency Injection
  • Supply voltage (AC): 200Vac-240Vac (208Vac / 220Vac / 230Vac)
  • Display: LED 5-digit display
  • Type of network: 3-phase input (3P)
  • Rated current: 30A (Normal duty), 25A (heavy duty), 120% / 60s (Normal duty) or 150% / 60s (heavy duty) overload current rating
  • Rated power (HP): 10HP (Normal duty), 7.5HP (7-1/2HP) (Heavy-duty)
  • Protection functions: Motor overheat, Overcurrent, Overload, Overvoltage, Under voltage, Momentary power loss ride-thru, Overheat, Ground fault
  • Protection settings: (Overcurrent) output current exceeds 200% of heavy duty rating, (Overload) 120% of rated output current; normal duty, (Overload) 150% of rated output current; heavy duty
  • Communication protocol: RS-422, RS-485
  • Mounting mode: Wall mounting
  • Digital inputs: 1 x digital input (24Vdc; Sink/Source) (S1 – Forward / Stop)
    • 1 x digital input (24Vdc; Sink/Source) (S2 – Reverse / Stop)
    • 1 x digital input (24Vdc; Sink/Source) (S3 – External fault)
    • 1 x digital input (24Vdc; Sink/Source) (S4 – Fault reset)
    • 1 x digital input (24Vdc; Sink/Source) (S5 – Multi-step speed 1)
    • 1 x digital input (24Vdc; Sink/Source) (S6 – Multi-step speed 2)
    • 1 x digital input (24Vdc; Sink/Source) (S7 – Jog speed)
    • 1 x digital input (24Vdc; Sink/Source) (S8 – External Baseblock)
    • 1 x digital input (Pulse train input)
  • Digital outputs: 1 x digital output (SPDT Single Pole Double Throw contact type) (MA-MB-MC; MC-MB closed means fault)
    • 1 x digital output (NO Normally Open contact type / Multi-function contact output) (M1-M2)
    • 1 x digital output (NO Normally Open contact type / Multi-function contact output (Zero speed) contact) (M3-M4)
    • 1 x digital output (NO Normally Open contact type / Multi-function (Speed agree 1) contact output) (M5-M6)
    • 1 x digital output (multi-function pulse train) (MP)
  • Analog inputs: 1 x analog input (-10…+10Vdc / 20kΩ) (Analog Input 1 – Frequency reference bias)
    • 1 x analog input (0-20mA / 4-20mA / -10…+10Vdc / 250Ω) (Analog Input 2 – Frequency reference bias)
    • 1 x analog input (-10…+10Vdc / PTC input) (Analog input 3 – Aux. frequency reference or motor temperature)
  • Analog outputs: 1 x analog output (4-20mA / -10…+10Vdc) (FM – to output frequency meter)
    • 1 x analog output (4-20mA / -10…+10Vdc) (AM – to output current meter)
  • Degree of protection: IP20, NEMA 1
  • Ambient air temperature for storage: -20…+60 °C
  • Technology used in component: Forced ventilation (Fan-cooling), Standard heatsink fins
  • Rated apparent power (S): 11.4kVA (Normal duty), 9.5kVA (heavy duty)
  • Application type: HVAC, Fans, Pumps, Compressors, Conveyors, Machine Tools, Extruders, Punching Presses, Winders
  • Order code / Manufacturer SKU: CIMRAU2A0030FAA
  • Manufacturer product status: Commercialized
  • Compliant with standard(s): UL 508C, CSA C22.2, IEC 61508, IEC 61800-5-1

Additional information

Weight24 lbs
Dimensions12 × 10 × 18 in