Yaskawa CIMR-AU4A0009FAA AC Drive 5HP 8.8A CIMRAU4A0009FAA
$1,460.00
AVAILABILITY: In Stock Can Ship Right Now
2 in stock
Description
Yaskawa CIMR-AU4A0009FAA AC Drive 5HP 8.8A CIMRAU4A0009FAA
- Extended Product Type: AC Drives
- Product ID: CIMR-AU4A0009FAA
- Yaskawa Type Designation: AC Drives
Description of Yaskawa CIMR-AU4A0009FAA AC Drive 5HP
Yaskawa CIMR-AU4A0009FAA Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) / Inverter – USA region – Yaskawa (A1000 series) – Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac / 415Vac / 440Vac) – Rated active power 5HP (Normal duty) – Rated output current 8.8A (Normal duty) – frequency (output) 0.01-400Hz – IP20 / NEMA 1 – with RS-422 + RS-485 communication capability – Wall mounting – Forced ventilation (Fan-cooling) (Standard heatsink fins) – 3-phase 480V class – ordering code CIMRAU4A0009FAA
Specification of Yaskawa CIMR-AU4A0009FAA AC Drive 5HP 8.8A
- Primary brand: Yaskawa
- Main function: Variable Speed/Frequency Drive (VSD/VFD) / Inverter
- Product series / family name: A1000 series
- Network frequency: (output) 0.01-400 Hz, (input) 50/60 Hz
- Functions: Multi-purpose Variable Speed/Frequency Drive (VSD/VFD) / Inverter – USA region, Droop Control, Speed/torque Control Switching, Feed Forward Control, Zero servo function, Speed search, Over torque-detection, Under-torque detection, Torque limit, 17-step speed, Acceleration/Deceleration time switch, S-curve acceleration/deceleration, 3-wire sequence, Auto-tuning, Dwell, Cooling fan on/off switch, Slip compensation, Torque compensation, Frequency jump, Upper/lower limits for frequency reference, DC injection braking at start and stop, Overexcitation braking, High slip braking, PID control, Energy saving control, Fault restart, Application presets, Backup, Online tuning, KEB, Overexcitation deceleration, Inertia (ASR) tuning, High Frequency Injection
- Supply voltage (AC): 380Vac-480Vac (400Vac / 415Vac / 440Vac)
- Display: LED 5-digit display
- Type of network: 3-phase input (3P)
- Rated current: 8.8A (Normal duty), 7.2A (heavy duty), 120% / 60s (Normal duty) or 150% / 60s (heavy duty) overload current rating
- Rated power (HP): 5HP (Normal duty), 4HP (Heavy-duty)
- Protection functions: Motor overheat, Overcurrent, Overload, Overvoltage, Under voltage, Momentary power loss ride-thru, Overheat, Ground fault
- Protection settings: (Overcurrent) output current exceeds 200% of heavy duty rating, (Overload) 120% of rated output current; normal duty, (Overload) 150% of rated output current; heavy duty
- Communication protocol: RS-422, RS-485
- Mounting mode: Wall mounting
- Digital inputs: 1 x digital input (24Vdc; Sink/Source) (S1 – Forward / Stop)
- 1 x digital input (24Vdc; Sink/Source) (S2 – Reverse / Stop)
- 1 x digital input (24Vdc; Sink/Source) (S3 – External fault)
- 1 x digital input (24Vdc; Sink/Source) (S4 – Fault reset)
- 1 x digital input (24Vdc; Sink/Source) (S5 – Multi-step speed 1)
- 1 x digital input (24Vdc; Sink/Source) (S6 – Multi-step speed 2)
- 1 x digital input (24Vdc; Sink/Source) (S7 – Jog speed)
- 1 x digital input (24Vdc; Sink/Source) (S8 – External Baseblock)
- 1 x digital input (Pulse train input)
- Digital outputs: 1 x digital output (SPDT Single Pole Double Throw contact type) (MA-MB-MC; MC-MB closed means fault)
- 1 x digital output (NO Normally Open contact type / Multi-function contact output) (M1-M2)
- 1 x digital output (NO Normally Open contact type / Multi-function contact output (Zero speed) contact) (M3-M4)
- 1 x digital output (NO Normally Open contact type / Multi-function (Speed agree 1) contact output) (M5-M6)
- 1 x digital output (multi-function pulse train) (MP)
- Analog inputs: 1 x analog input (-10…+10Vdc / 20kΩ) (Analog Input 1 – Frequency reference bias)
- 1 x analog input (0-20mA / 4-20mA / -10…+10Vdc / 250Ω) (Analog Input 2 – Frequency reference bias)
- 1 x analog input (-10…+10Vdc / PTC input) (Analog input 3 – Aux. frequency reference or motor temperature)
- Analog outputs: 1 x analog output (4-20mA / -10…+10Vdc) (FM – to output frequency meter)
- 1 x analog output (4-20mA / -10…+10Vdc) (AM – to output current meter)
- Degree of protection: IP20, NEMA 1
- Ambient air temperature for storage: -20…+60 °C
- Technology used in component: Forced ventilation (Fan-cooling), Standard heatsink fins
- Rated apparent power (S): 6.7kVA (Normal duty), 5.5kVA (heavy duty)
- Application type: HVAC, Fans, Pumps, Compressors, Conveyors, Machine Tools, Extruders, Punching Presses, Winders
- Order code / Manufacturer SKU: CIMRAU4A0009FAA
- Manufacturer product status: Commercialized
- Compliant with standard(s): UL 508C, CSA C22.2, IEC 61508, IEC 61800-5-1
Additional information
Weight | 18 lbs |
---|---|
Dimensions | 14 × 12 × 18 in |
Brand
Yaskawa
Discover Excellence with Yaskawa Brands at automationpioneer. Unleash Precision and Performance. Shop Now for Cutting-Edge Industrial Automation Solutions!
#Yaskawa industrial automation #Precision automation solutions #Yaskawa products online #Cutting-edge industrial tech #Yaskawa robotics #Industrial automation excellence #Yaskawa brand offerings #Precision performance tools #Advanced automation solutions #Yaskawa shop by brands
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.